UL Standard |
CSA Standard |
ANCE Standard |
UL Standard Title |
Harmonization |
5A |
62.1 |
N/A |
Surface Nonmetallic Raceways |
Binational |
6 |
45.1 |
534 |
Electrical Rigid Metal Conduit -- Steel |
Trinational |
6A |
C22.2 No. 45-2-08 |
576 |
Electrical Rigid Metal Conduit -- Aluminum, Red Brass |
Trinational |
20 |
111 |
N/A |
General-Use Snap Switches |
Binational |
44 |
38 |
451 |
Thermoset-Insulated Wires and Cables |
Trinational |
50 |
94.1 |
235/1 |
Enclosures for Electrical Equipment, Non- Environmental Considerations |
Trinational |
50E |
94.2 |
235/2 |
Enclosures for Electrical Equipment, Environmental Considerations |
Trinational |
62 |
49 |
436 |
Flexible Cord and Fixture Wire |
Trinational |
83 |
75 |
10 |
Thermoplastic-Insulated Wires and Cables |
Trinational |
98 |
4 |
162 |
Enclosed and Dead-Front Switches |
Trinational |
218 |
263 |
626 |
Fire Pump Controllers |
Trinational |
224 |
198.1 |
N/A |
Extruded Insulating Tubing |
Binational |
248-1 |
248.1 |
009/248/1 |
Low-Voltage Fuses - Part 1: General Requirements l |
Trinational |
248-10 |
248.1 |
009/248/10 |
Low-Voltage Fuses - Part 10: Class L Fuses |
Trinational |
248-11 |
248.11 |
009/248/11 |
Low-Voltage Fuses - Part 11: Plug Fuses |
Trinational |
248-12 |
248.12 |
009/248/12 |
Low-Voltage Fuses - Part 12: Class R Fuses |
Trinational |
248-13 |
248.13 |
009/248/13 |
Low-Voltage Fuses - Part 13: Semiconductor Fuses |
Trinational |
248-14 |
248.14 |
009/248/14 |
Low-Voltage Fuses - Part 14: Supplemental Fuses |
Trinational |
248-15 |
248.15 |
009/248/15 |
Low-Voltage Fuses - Part 15: Class T Fuses |
Trinational |
248-16 |
248.16 |
009/248/16 |
Low-Voltage Fuses - Part 16: Test Limiters |
Trinational |
248-2 |
248.2 |
009/248/2 |
Low-Voltage Fuses - Part 2: Class C Fuses |
Trinational |
248-3 |
248.3 |
009/248/3 |
Low-Voltage Fuses - Part 2: Class C Fuses |
Trinational |
248-4 |
248.4 |
009/248/4 |
Low-Voltage Fuses - Part 4: Class CC Fuses |
Trinational |
248-5 |
248.5 |
009/248/5 |
Low-Voltage Fuses - Part 5: Class G Fuses |
Trinational |
248-6 |
248.6 |
009/248/6 |
Low-Voltage Fuses - Part 6: Class H Non-Renewable |
Trinational |
248-7 |
248.7 |
009/248/7 |
Low-Voltage Fuses - Part 7: Class H Renewable Fuse |
Trinational |
248-8 |
248.8 |
009/248/8 |
Low-Voltage Fuses - Part 8: Class J Fuses |
Trinational |
248-9 |
248.9 |
009/248/9 |
Low-Voltage Fuses - Part 9: Class K Fuses |
Trinational |
310 |
153 |
N/A |
Electrical Quick-Connect Terminals |
Binational |
347 |
253 |
564/106 |
Alternating Current Contactors and Contactor-Based |
Trinational |
467 |
41 |
N/A |
Grounding and Bonding Equipment |
Binational |
486A-486B |
65 |
543 |
Wire Connectors |
Trinational |
486C |
188 |
548 |
Splicing Wire Connectors |
Trinational |
486D |
198.2 |
NMX-J-519 |
Sealed Wire Connector Systems |
Trinational |
489 |
C22.2 No. 5 |
NMX-J-266 |
Molded-Case Circuit Breakers, Molded-Case Switches |
Trinational |
496 |
43 |
N/A |
Lampholders |
Binational |
514A |
18.1 |
023/1 |
Metallic Outlet Boxes |
Trinational |
514B |
18.3 |
NMX-J-017 |
Conduit, Tubing, and Cable Fittings |
Trinational |
514D |
42.1 |
N/A |
Cover Plates for Flush-Mounted Wiring Devices |
Binational |
568 |
126.2 |
N/A |
Nonmetallic Cable Tray Systems |
Binational |
797 |
83.1 |
536 |
Electrical Metallic Tubing -- Steel |
Trinational |
845 |
254 |
353 |
Motor Control Centers |
Trinational |
857 |
27 |
148 |
Busways |
Trinational |
891 |
244 |
118/2 |
Switchboards |
Trinational |
943 |
144.1 |
NMX-J-520-AN |
Ground-Fault Circuit-Interrupters |
Trinational |
1441 |
198.3 |
N/A |
Coated Electrical Sleeving |
Binational |
1472 |
184.1 |
N/A |
Solid-State Dimming Controls |
Binational |
1565 |
18.5 |
N/A |
Positioning Devices |
Binational |
1598 |
250.2 |
307/1 |
Luminaires |
Trinational |
UL Standard |
CSA Standard |
ANCE Standard |
UL Standard Title |
Harmonization |
1653 |
227.1 |
N/A |
Electrical Nonmetallic Tubing |
Binational |
1660 |
227.2 |
N/A |
Liquid-Tight Flexible Nonmetallic Conduit |
Binational |
1682 |
182.1 |
N/A |
Plugs, Receptacles, and Cable Connectors of the Pin |
Binational |
1684 |
211.3 |
N/A |
Reinforced Thermosetting Resin Conduit (RTRC) and |
Binational |
1696 |
227.3 |
N/A |
Nonmetallic Mechanical Protection Tubing |
Binational |
1786 |
256 |
N/A |
Direct Plug-In Nightlights |
Binational |
1993 |
1993 |
578 |
Self-Ballasted Lamps |
Trinational |
1995 |
236 |
N/A |
Heating And Cooling Equipment |
Binational |
2239 |
18.4 |
N/A |
Hardware for the Support of Conduit, Tubing, and Cab |
Binational |
2420 |
2420 |
N/A |
Belowground Reinforced Thermosetting Resin Conduit |
Binational |
2459 |
2459 |
N/A |
Insulated Multi-pole Splicing Wire Connectors |
Binational |
2515 |
2515 |
N/A |
Aboveground Reinforced Thermosetting Resin Condui |
Binational |
2556 |
2556 |
556 |
Wire and Cable Test Methods |
Trinational |
4248-1 |
4248.1 |
009/4248/1 |
Fuseholders - Part 1: General Requirements |
Trinational |
4248-11 |
4248.11 |
009/4248/11 |
Fuseholders - Part 11: Type C (Edison Base) and Typ |
Trinational |
4248-12 |
4248.12 |
009/4248/12 |
Fuseholders - Part 12: Class R |
Trinational |
4248-15 |
4248.15 |
009/4248/15 |
Fuseholders - Part 15: Class T |
Trinational |
4248-4 |
4248.4 |
009/4248/4 |
Fuseholders - Part 4: Class CC |
Trinational |
4248-5 |
4248.5 |
009/4248/5 |
Fuseholders - Part 5: Class G |
Trinational |
4248-6 |
4248.6 |
009/4248/6 |
Fuseholders - Part 6: Class H |
Trinational |
4248-8 |
4248.8 |
009/4248/8 |
Fuseholders - Part 8: Class J |
Trinational |
4248-9 |
4248.9 |
009/4248/9 |
Fuseholders - Part 9: Class K |
Trinational |
60335-2-24 |
60335-2-24 |
521-2-24 |
Household and Similar Electrical Appliances, Part 2: |
Trinational-IEC |
60947-1 |
60947-1-07 |
N/A |
Low-Voltage Switchgear and Controlgear - Part 1: Gen |
Trinational-IEC |
60947-4-1A |
60947-4-1-07 |
290 |
Low-Voltage Switchgear and Controlgear - Part 4-1: C |
Trinational-IEC |
62275 |
18.5 |
623 |
Cable management systems - Cable ties for electrical |
Trinational-IEC |